PRINTED CIRCUIT BOARD

1. CIRCUIT CHECK PROCEDURE

1. Low voltage transformer check

The low voltage transformer is located on the P.C.B.
Measuring condition: Input voltage: 120V / Frequency: 60Hz

2. Voltage Check

- Key check point

- Check method

NOTE
1. Refer to Ciruit Diagram (point 4).
2. Secondary side voltage of the low voltage transformer changes in proportion to fluctuation of power source

voltage.

3. The allowable tolerance of the secondary voltage is within

NOTE
Each measure point must be measured with GND points.

Terminal Voltage

4-7

LOAD

AC 12.6 V

NO LOAD

AC 14.7 V

NO

CHECK POINT

REMARK

1

IC1 PIN 2, 21, 30, 34

-5VDC

2

IC1 PIN 35

3

IC1 PIN 31 OR 32

T : 16.67ms(60Hz)

T : 250 ns(4MHz)

NO

MEASURE POINT

WAVE FORM

REMEDY

REMARK

1

MP1

Replace VL1, EC1

NO LOAD

2

MP2

Replace EC2, D12,13,14

NO LOAD