CONDITION

CHECK

RESULT

Check continuity of high

voltage capacitor terminals

with wires removed

Continuity

CAUSE

Defective high

voltage

transformer

REMEDY

Replace

No

microwave

oscillation

Check continuity of high voltage

rectifier in forward and backward

direction with DC megger

Continuity in

backward

direction

Defective high

voltage rectifier

Replace

Connect megger leads to

magnetron terminal and

magnetron body

Continuity

Defective

magnetron

Replace

Check resistance of primary and

secondary coil of high voltage

transformer

0 or

Defective high

voltage

transformer

Replace

Check continuity of magnetron

with wires removed

No

Continuity

Defective

magnetron

Replace

Check continuity of filament

terminal of high voltage

transformer

No

Continuity

Defective high

voltage

transformer

Replace

Check D.C. voltage being

supplied to RELAY (RY1) coil

0 V

Defective touch

control circuit

Replace

Approx

15 VDC

Faulty

contacts or

RELAY (RY1)

or open

relay coil

Replace

(TROUBLE 3) No microwave oscillation even though fan motor rotates.

21