beautypg.com

Troubleshooting – Dixon 5000 Series User Manual

Page 49

background image

TROUBLESHOOTING

ELECTRICAL SYSTEM:

Starter will not
turn engine over

Circuit breaker engaged

Push button to reset Consult
your dealer for repair

Battery discharge

Poor connections on

battery

Battery water low

Wrong battery installed

in mower

Tighten or replace as required

Battery discharge

Engine electrical system
not functioning correctly

Have electrical system checked by
your dealer

Battery discharge

Engine being operated
at too low an RPM

Increase engine RPM

Contact your dealer for information

NOTE: Electrical system failures are generally simple in nature, always check the obvious first

and then move onto the more complicated parts used. Poor battery service, loose
connections, corrosion, frayed or broken wiring, are more likely than component failure.

CAUSES

SITUATION

REMEDY

Starter will not
turn engine over

Dead battery

Charge battery