PROBLEM

POSSIBLE CAUSE

CORRECTION

Loss of Vacuum.

Blower, hose or hood inlet clogged.

Remove hose and clean inlet.

Hopper full.

Inspect and empty.

Fan blades bent or broken.

Replace/repair impeller.

Poly mesh plugged.

Clean poly mesh.

Unusual vibration

Solid object jammed in unit.

Check and remove any

or noise

obstruction.

Loose or missing bolts on unit.

Tighten or replace bolts.

Bent or damaged fan.

Replace/repair impeller.

Unit difficult to close.

Obstructions keeping door

Clear obstructions.

from completely closing.

Hood hinge bolts too tight.

Loosen bolts.

Troubleshooting Guide

DANGER

Before servicing unit, wait for all moving parts to
come to a complete stop. Turn engine off and
remove the spark plug wire.

Caring For Hoses

1.

Inspect hoses before each use. If hoses have
excessive wear, tears, or punctures, replace
immediately.

2.

To prolong the life of the hose, periodically rotate
hose and turn hose end to end. Refer to
Preventative Maintenance Schedule in this
manual.

3.

Avoid twists and sharp turns in the hoses, as they
will increase wear on the hoses.

4.

Avoid dragging the lower hose along the sides of
buildings or other hard surfaces.

SERVICE AND MAINTENANCE

Cleaning Poly Mesh

The poly mesh on the collection system is located
inside the container hood. For best results, clean poly
mesh regularly.

DO NOT USE THE COLLECTION SYSTEM WITHOUT
POLY MESH SECURELY IN PLACE.