Installation and operating instructions – Louroe Electronics MS-2-REC User Manual
Page 2
![background image](https://www.manualsdir.com/files/795163/content/doc002.png)
MICROPHONE CONNECTION
All Louroe Microphones have a 3-pin terminal block marked A, B, C
A = 12Vdc Power
B = Audio Output
C = Ground
Bring twisted pair cable 22 or 20 gauge to microphone terminal block and connect as follows:
1) Connect 1 of the wires to pin A of microphone
2) Connect other wire to pin C of microphone
Run other end of twisted pair cable to the MS-2-REC plate
MS-2-REC MUTE SWITCH CONNECTION
Carefully matching color codes, connect as follows:
1) Connect wire from Pin A of Microphone to Pin A1 of MS-2-REC
2) Connect wire from Pin C of Microphone to Pin C of MS-2-REC
CONNECTION FROM MICROPHONE TO RECORDING DEVICE
Wiring Requirements:
Single conductor shielded, 22 gauge with a 24 gauge drain wire
This wire will have a jacket color (black, red, etc.). Drain wire is bare.
Bring one end of shielded cable to microphone 3-pin terminal block.
1) Jacketed wire (colored) connects to pin B of microphone
2) Drain wire (bare) connects to pin C (shared with twisted wire)
Run other end of shielded cable to recording device. If the Audio Input of recorder is an RCA Jack, solder on
an RCA plug as follows:
1) The jacketed wire attached to Pin B of microphone goes to positive tip of RCA Plug (positive)
2) The bare wire attached to Pin C of microphone goes to the sleeve (negative)
Connect to “Audio In” of recording device.
If Audio Input of recording device is other than RCA, refer to manufacturers instructions for connection.
CONNECTION FROM MS-2 REC TO RECORDING DEVICE OR OTHER
Wiring Requirements:
Twisted pair, 20 or 22 gauge
1) Connect one wire to pin R1 of MS-2-REC
2) Connect other wire to pin R2 of MS-2-REC
Run other end of twisted pair to recorder’s or other receiving device contacts. Refer to recorder’s
manufacturers installation instruction for details of contact connections.
MS-2-REC has a 5-pin terminal block marked A, A1, C, R1 and R2
A = 12Vdc Power
A1 = Power to Microphone
C = Ground
R1 = Connection to Recorder Contact
R2 = Connection to Recorder Contact
INSTALLATION AND OPERATING INSTRUCTIONS
Page 2 of 8
LOUROE ELECTRONICS 6 9 5 5 VA L J E A N AVENUE, VAN NUYS, CA 91406
TEL (818) 994-6498
FAX
994-6458
website: www.louroe.com e-mail: [email protected]
(818)
®
ms-2rec_inst_4/15