SENSITIVITY SWITCH OF MICROPHONE
For special installations that require less microphone sensitivity, a sensitivity switch has been added
to the microphone pre-amp (PC board) and has two positions - N and L:
N represents normal sensitivity (0dB output into 1KW
)
L represents low sensitivity (-6dB output into 1 KW
)
NOTE: Louroe Verifact microphones are always shipped with the sensitivity switch in
normal (N) position. Do not change unless required.
Should an adjustment be necessary, locate the small red switch on the PC board mounted behind the
back side of the stainless face plate. Using a small tool, move the slide switch from N to L
SPECIFICATIONS
Sensitivity
-45 dB
Line Level (0 dBV, 600
W
@ 1kHZ)
Frequency response
50 Hz to 15 kHz
Output
Current drain
10 mA
DCS-1 DURESS CALL STATION
Page 3 of 4
LOUROE ELECTRONICS 6 9 5 5 VA L J E A N AVENUE, VAN NUYS, CA 91406
TEL (818) 994-6498
FAX
994-6458
website: www.louroe.com e-mail: [email protected]
(818)
®
INSTALLATION AND OPERATING INSTRUCTIONS
Tone output
3 Vrms into 10K
load @ 3 kHz
Supply voltage
12 Vdc
Dimensions
Weight
Shipping Weight
4 1/2“ L x 2 3/4“ W
4 oz
1 lb
dcs-1_inst_3/15