beautypg.com

Installation and operating instructions c, Model dcs – Louroe Electronics DCS-1 User Manual

Page 2

background image

The PC board of DCS-1 contains a barrier block with four terminals marked 1, 2, 3 and 4.

1 - Ground or common
2 - Jumper (installed by factory). This terminal not used with DCS-1
3 - Output of Oscillator
4 - +12Vdc Power

WIRING CONNECTION TO DCS-1 DURESS CALL STATION

CONNECTION TO MODEL DG-12II OR DG-25III ALARMING BASE STATION

Located on rear panel are 12 or 25 sets of 5-pin headers marked A, B, C, SP and G. Connect:

Red wire to pin A
Black wire to pin B
Bare wire to pin C

Pins SP and G are not used with this application

Refer to installation/operation instructions of ALA-4/ALA-8 and

DG-12II/DG-25III for additional information

WIRE COLOR CODE OF WEST PENN 452

- 12Vdc

BLACK

- Audio Output
- Ground

If using wiring from other manufacturers,
color code may vary.

RED

BARE

Page 2 of 4

LOUROE ELECTRONICS 6 9 5 5 VA L J E A N AVENUE, VAN NUYS, CA 91406

TEL (818) 994-6498

FAX

994-6458

website: www.louroe.com e-mail: [email protected]

(818)

®

INSTALLATION AND OPERATING INSTRUCTIONS

C

2

B

3

A

4

TO TERMINAL BLOCK OF

LOUROE DG SERIES BASE

STATION

REFER TO THE SPECIFIC BASE

STATION

INSTALLATION INSTRUCTIONS

FOR PROPER

CONNECTIONS

MODEL DCS

BLACK

BLACK

BARE

BARE

RED

RED

2 Conductor shielded cable, 22
gauge with a 24 gauge drain wire

NOTE:

Unshielded cable is not

satisfactory for audio systems

WIRING REQUIREMENTS

West Penn 452 or equivalent

1

dcs-1_inst_3/15