beautypg.com

Test functions, Specifications – Dynacord DTI 2000 User Manual

Page 14

background image

DTI 2000 Manual e EDITED.doc

14

Test Functions

The processor system automatically runs an initial self-test whenever the DTI 2000 is connected to the
mains. During this procedure, first the red DROP LED should light. Afterwards, the orange TALK
LED blinks for approximately 3 seconds. In case faulty operation is being recognized, the processor
system stops and the DROP and TALK LEDs light. Otherwise the

DROP LED

is dimmed and only

the red

DROP LED

lights as long as a telephone connection has not been established.

Pressing the SEIZE / DROP button on the front panel manually establishes a connection (pick up) or

drops a connection (hang up). When the button is used to “take a call”, the green SEIZE LED should
light and the red DROP LED should be dimmed. Pressing the key once again drops the connection and
the red LED lights while the green LED is dimmed.

The orange TALK LED lights when the DTI 2000 is in announcement mode (i.e. when a telephone
announcement in a single or several zones of the PA-system has been activated).

Specifications

Audio Output level

0 dBu ... +20dBu

Telephone Input Level

-30 dBu ... +6 dBu

S/N Ratio

> 60 dB (200 Hz ... 3.8 kHz)

Frequency Response

300 Hz ... 3.8 kHz (+0 / -6 dB)


Phone Line Connectors

2 x RJ-11 (Line / Loop Thru)

DPM 4000 Interface

RJ-12, DB-9 sockets


Power Supply

100 ... 240 V AC, 50 / 60 Hz

Temperature Range during Operation 0 °C … 50 °C
Dimensions

208 x 44 x 203 mm (B x H x T), ½ 19“ / 1 HU

Weight

2.0

kg

Certifications

CE,

UL,

FCC


- Design and specifications are subject to changes without further
notice -