Lacava llc 6 – Lacava EX03 User Manual

Page 6

background image

LACAVA LLC

6

TEMPORARY OFF FUNCTION

DELAY IN TIME

DETECTION RANGE

DELAY OUT TIME

R E S E T

E N T R A N C E T O T H E

S E L F A D J U S T M E N T M O D E

LOCK OUT TIME

24 HOUR HYGIENE FLUSH

Adjusting the settings with the remote control
If necessary, the sensor settings can be adjusted as follows:
Shut off the water supply. In order to adjust the sensor with the remote control,

hold the remote control straight in front of the sensor in a distance of about

6-8” (15-20cm). Choose the function you want to adjust by pressing once on

the function buttons. After pressing once on a specific function button, a

quick flashing of the red light at the front of the sensor will occur. At this stage,

you can change the setting by pressing the (+) or the (-) buttons, every push will

increase or decrease one level. After finishing the adjustment, turn the water

supply back on.

DETECTION RANGE This faucet was supplied with a Self Adjusting

Sensor. The ideal detection range for the

location will be

set automatically.
Only if necessary, use the remote control to adjust the sensor

range as follows:
Press the RANGE button. Wait until a quick flashing of the red light of

the sensor eye is perceived. Then, press + to increase the delay out

time and – to reduce it. Every push will increase or decrease one

level.

ENTRANCE TO THE SELF ADJUSTMENT MODE

Check that no objects are in front of the sensor.

Press the ADJ button. Once a quick flashing of the red light of the

sensor eye is perceived, remove your hand holding the remote

control and move away from the sensor area. The ideal sensor

range for the specific location will be set automatically.

Once the self adjustment has taken place the solenoid valve will be

opened and closed for 1 second as an indication that the ideal sensor

range was set and the product is ready for use.

SECURITY TIME The Security time, prevents continuous running

of water due to reflections or vandalism. By default, if the sensor

is covered for more than 90 seconds the water flow will shut

automatically. To resume regular operation any obstruction must be

removed.
Press the SEC button. Wait until a quick flashing of the red light of the

sensor eye is perceived. Then, press + to increase the security time

and – to reduce it.