Wiring diagram, 7hite, Factory recommended g.f.c.i. load center wiring – Dynasty Spas 2008 User Manual
Page 10: Wiring requirements, Caution
Dynasty Spas Operator’s Guide • www.dynastyspas.com
10
Factory Recommended G.F.C.I. Load Center Wiring
WIRING DIAGRAM
Note: The white neutral wire from the back of the GFCI MUST be
connected to an incoming line neutral. The internal mechanism of the
GFCI requires this neutral connection. The GFCI will not work without it.
Wiring Requirements
•
The bonding wire at least No. 8 AWG copper wire.
• Pull Copper current carrying conductors (one each: black, red, white,
green), Use either No. 6 AWG 60º C, 8 AWG 75º C, or No. 8 AWG 90º C
wire, if spa is 50 feet or less away from its power supply. Note: the ground
must be equal to or larger than the largest power conductor.
7HITE
:KLWH3LJWDLO
:KLWH3LJWDLO
1HXWUDO%DU
1HXWUDO%DU
:KLWH)U
RP6SD
3PA
,
.
,
'
;0
./4%
Note: Connection order may vary by pack model, please refer to
equipment pack panel for proper connection order.