RESETTING THE INDOOR AND OUTDOOR MAXI-
MUM/ MINIMUM RECORDS
Press and hold the MIN/MAX key for about 2 seconds,
this will reset all the indoor and outdoor MIN/MAX tem-
perature records to the current indoor and outdoor
temperatures.
915 MHz RECEPTION
The Temperature station should receive the tempera-
ture data within 1 minute after set-up. If the tempera-
ture data is not received 1 minute after setting up (not
successfully continuously, the outdoor display shows
“- - -”), please check the following points:
1. The distance of the temperature station or trans-
mitter should be at least 5-6 feet away from any
interfering sources such as computer monitors or
TV sets.
2. Avoid positioning the Temperature station onto or
in the immediate proximity of metal window frames.
3. Using other electrical products such as headphones
or speakers operating on the same signal frequency
(915MHz) may prevent correct signal transmission
and reception.
4. Neighbours using electrical devices operating on
the 915MHz signal frequency can also cause
interference.
Note:
When the 915MHz signal is received correctly, do not
re-open the battery cover of either the transmitter or
Temperature station, as the batteries may spring free
from the contacts and force a false reset. Should this
happen accidentally then reset all units (see Setting
up above) otherwise transmission problems may occur.
The maximum transmission range is 330 feet (100 m)
from the transmitter to the Temperature station (in open
space). However, this depends on the surrounding
environment and interference levels. If no reception is
possible despite the observation of these factors, all
system units have to be reset (see Setting up).
MOUNTING
POSITIONING THE TEMPERATURE STATION
The Temperature Station has been designed to be hung
onto wall or free standing.
To wall mount
Choose a sheltered place. Avoid direct rain and
sunshine. Before wall mounting, please check that the
outdoor temperature values can be received from the
desired locations.
1. Fix a screw (not supplied) into the desired wall, leav-
ing the head extended out the by about 5mm.
2. Remove the stand from the Temperature Station
by pulling it away from the base and hang the sta-
tion onto the screw. Remember to ensure that it
locks into place before releasing.
Free standing
With the detachable stand, the temperature station can
be placed onto any flat surface.
POSITIONING THE TEMPERATURE TRANSMITTER
The Transmitter is supplied with a holder that may be
attached to a wall with the two screws supplied. The
Transmitter can also be position on a flat surface by
securing the stand to the bottom to the Transmitter.
To wall mount
1. Secure the bracket onto a desired wall using the
screws and plastic anchors.
2. Clip the remote temperature sensor onto the
bracket.
Note:
Before permanently fixing the transmitter wall base,
place all units in the desired locations to check that the
outdoor temperature reading is receivable. In event that
the signal is not received, relocate the transmitters or
move them slightly as this may help the signal reception.
CARE AND MAINTENANCE
•
Extreme temperatures, vibration and shock should
be avoided as these may cause damage to the unit
and give inaccurate forecasts and readings.
•
When cleaning the display and casings, use a soft
damp cloth only. Do not use solvents or scouring
agents as they may mark the LCD and casings.
•
Do not submerge the unit in water.
•
Immediately remove all low powered batteries to
avoid leakage and damage. Replace only with new
batteries of the recommended type.
•
Do not make any repair attempts to the unit. Re-
turn them to their original point of purchase for re-
pair by a qualified engineer. Opening and tamper-
ing with the unit may invalidate their guarantee.
•
Do not expose the units to extreme and sudden
temperature changes, this may lead to rapid
changes in forecasts and readings and thereby re-
duce their accuracy.
SPECIFICATIONS
Temperature measuring range
Indoor:
14.1˚F to +140˚F with 0.2˚F resolution
(“OF.L” displayed if outside this range)
Outdoor:
-3.8˚F to +140˚F with 0.2˚F resolution
(“OF.L” displayed if outside this range)
Indoor temperature
checking interval:
every 27.5 seconds
Outdoor data reception:
every 27.5 seconds
Transmission range:
100 meters
Power consumption
Temperature station:
2 x AA, IEC LR6, 1.5V
Temperature transmitter:
2 x AAA, IEC, LR3 1.5V
Battery life cycle (Alkaline batteries recommended)
Temperature station:
Approximately 24 months
Temperature transmitter: Approximately 12 months
Dimensions (H x L x W)
Temperature station:
3.85" x 2.91" x 1.14"
Temperature transmitter :
3.41" x 0.55" x 1.27"
WARRANTY INFORMATION
La Crosse Technology, Ltd provides a 1-year limited
warranty on this product against manufacturing defects
in materials and workmanship.
This limited warranty begins on the original date of
purchase, is valid only on products purchased and used
in North America and only to the original purchaser of
this product. To receive warranty service, the purchaser
must contact La Crosse Technology, Ltd for problem
determination and service procedures. Warranty ser-
vice can only be performed by a La Crosse Technology,
Ltd authorized service center. The original dated bill
of sale must be presented upon request as proof of
purchase to La Crosse Technology, Ltd or La Crosse
Technology, Ltd’s authorized service center.
La Crosse Technology, Ltd will repair or replace this
product, at our option and at no charge as stipulated
herein, with new or reconditioned parts or products if
found to be defective during the limited warranty pe-
riod specified above. All replaced parts and products