beautypg.com

Outline, load manager p – Kussmaul Electronics 091-141 User Manual

Page 6

background image

SPECIFICATION AND OUTLINE



Temperature Environment:

0 to 50 deg C.


Main Input Power:

12VDC Battery, [24VDC Battery]


Input Current:

90 [40] milliamperes, relay ON

9 [5] milliamperes, relay OFF


Load Output Power:

12VDC @ 30 amperes maximum.

[14VDC

@

30

Amperes

maximum]


Low Voltage Dropout of Load: 11.0 to 12.85 volts (potentiometer adjustable,

Factory set for 11 volts).

[21.25

to

24.75

volts

(potentiometer

adjustable,

Factory set for 22.0 volts)]


Load Power Restoration Voltage: .5 [.75] volt higher than the Low Voltage

dropout of load.


Time Dropout of Load:

1 to 2 hours (potentiometer adjustable, factory
set for 1 hour).


Starter Inhibit:

The Load will not drop out due to low voltage
while the engine is being started.


Weight:
0.5

lbs


OUTLINE, LOAD MANAGER P

3/16" DIA.

4,50

1.55

2.95

5.10