beautypg.com

Pump plus, Installation wiring diagram, Wire size chart – Kussmaul Electronics 091-9-1000 User Manual

Page 5

background image

Installation Wiring Diagram

4

3

2

1

PUMP PLUS

1000

BATTERY SAVER

OVER LOAD

POWER

DC

AC

AUTO

PUMP

COM

BAT1

POSITIVE

B.S.

+

AUTO

PUMP

CHARGER

Auto Charge 1000 Pump Plus

93.1

BAT

TER

Y

+

-

Battery Saver Loads

(3 amps max.).

When the charger

is disconnected from

120 volts AC the

Battery Saver loads

automatically are

connected to battery #1.

Chassis

Ground

Chassis

Ground

+

12

Volts

Accessories

1 2

3 4

5

CONNECTION

ITEM

DEFINITION

WIRE SIZE

COM

BATTERY COMMON

NEGATIVE CHARGING LEAD FOR CHARGING BATTERIES AND BATTERY SAVER LOAD

12 AWG

BAT 1

BATTERY #1

POSITIVE CHARGING LEAD FOR BATTERY # 1

12 AWG

B.S.

BATTERY SAVER

POSITIVE LEAD FOR BATTERY SAVER LOADS.

16 AWG

AUTO PUMP+ AUTO PUMP

AUTO PUMP, POSITIVE

14 AWG

AUTO PUMP- AUTO PUMP

AUTO PUMP, NEGATIVE

14 AWG

IMPORTANT: Wire size is for a maximum lenght of 10 feet. If longer, larger wiring is required.

WIRE SIZE CHART

BLK

BLK

RED

RED

Auto Pump

Air Compressor

BLACK

RED

Pressure

Switch

R

E

D

BL

AC

K

15

BLK

BLK

RED

RED

NOTE: Pin 1 of indicator must go to Pin 1

of Remote Display on charger.

Pin 2 of indicator must go to Pin 2

of Remote Display on charger, and

so forth. Check connections and

color of wires before plugging-in.

INDICATOR