Pump plus, Installation wiring diagram, Wire size chart – Kussmaul Electronics 091-9-1000 User Manual
Page 5
Installation Wiring Diagram
4
3
2
1
PUMP PLUS
1000
BATTERY SAVER
OVER LOAD
POWER
DC
AC
AUTO
PUMP
COM
BAT1
POSITIVE
B.S.
+
AUTO
PUMP
CHARGER
Auto Charge 1000 Pump Plus
93.1
BAT
TER
Y
+
-
Battery Saver Loads
(3 amps max.).
When the charger
is disconnected from
120 volts AC the
Battery Saver loads
automatically are
connected to battery #1.
Chassis
Ground
Chassis
Ground
+
12
Volts
Accessories
1 2
3 4
5
CONNECTION
ITEM
DEFINITION
WIRE SIZE
COM
BATTERY COMMON
NEGATIVE CHARGING LEAD FOR CHARGING BATTERIES AND BATTERY SAVER LOAD
12 AWG
BAT 1
BATTERY #1
POSITIVE CHARGING LEAD FOR BATTERY # 1
12 AWG
B.S.
BATTERY SAVER
POSITIVE LEAD FOR BATTERY SAVER LOADS.
16 AWG
AUTO PUMP+ AUTO PUMP
AUTO PUMP, POSITIVE
14 AWG
AUTO PUMP- AUTO PUMP
AUTO PUMP, NEGATIVE
14 AWG
IMPORTANT: Wire size is for a maximum lenght of 10 feet. If longer, larger wiring is required.
WIRE SIZE CHART
BLK
BLK
RED
RED
Auto Pump
Air Compressor
BLACK
RED
Pressure
Switch
R
E
D
BL
AC
K
15
BLK
BLK
RED
RED
NOTE: Pin 1 of indicator must go to Pin 1
of Remote Display on charger.
Pin 2 of indicator must go to Pin 2
of Remote Display on charger, and
so forth. Check connections and
color of wires before plugging-in.
INDICATOR