INSTALLATION WIRING DIAGRAM

IMPORTANT:
NOTE1: Wire size is for a maximum length of 20 feet. If wiring is to be longer,
larger wiring is required. Additional information is available on request.
NOTE2: If fuse is blown, to reset wait 5 minutes for cooling and press the fuse
switch on the front panel.

115VAC
Shore line

FUSE

POWER

OUTPUT

+

+

REMOTE
DISPLAY

24 V

BAT 2

12 V

BAT 1

AUTO CHARGE

24/12 HO

R

Chassis

Ground

Chassis

Ground

Chassis

Ground

Optional Bar-graph
Indicator
B091-39-001

24V Battery

Bank

12V Battery
Bank

16 AWG

12 AWG