beautypg.com

Calibration, Cw increases voltage, Voltage adjustments auto isolator 1 – Kussmaul Electronics 091-139-2-12 User Manual

Page 5: Figure 3

background image

CALIBRATION

The voltage setpoints may be altered in the field to suit particular customer requirements.

Adjustments are provided to adjust the main battery voltage at which the paralleling solenoid

is energized. An additional adjustment permits adjusting the voltage below which the auxiliary

battery will not be paralleled for starting boost.

MAIN BATTERY VOLTAGE ADJUST

AUXILIARY BATTERY VOLTAGE ADJUST

INDICATOR ILLUMINATED WHEN MAIN
BATTERY VOLTAGE IS ABOVE SETPOINT

13.0 VOLTS

INDICATOR ILLUMINATED WHEN

AUXILIARY BATTERY VOLTAGE IS
ABOVE SETPOINT, 12.4 VOLTS

MEASURE AUX. BAT. VOLTAGE HERE

MEASURE MAIN BAT. VOLTAGE HERE

ILLUMINATES DURING
ENGINE CRANKING

CW INCREASES VOLTAGE

Figure 3

VOLTAGE ADJUSTMENTS

AUTO ISOLATOR 1

R20

CR3

CR4

R16

I3

U5

U2

I4

8

7

6

5

4

3

2

1

C4

U4

R2

R21

R1

R3

U3

+

C5

C3

C2

+

R11

R1

2

R9

I2

CR2

CR1

J1

R7

R18

R8

R1

5

STARTER

MAIN
BAT.
OK

AUX.

BAT.
OK

OU

TP

UT

MAIN

AUX.

CI1

R10

KUSSMAUL ELECTRONICS CO

B091-139-002

R6

C6

R1

3

C7

I1

R4

R1

9

R1

7

Q1

GN

D

VCC

+

C1

U1

AUX

MAIN