INTRODUCTION

The Model 091-150-115 Auto Pump Timer limits the duty cycle of the Auto Pump to 1 hour “ON”

and 1 hour “OFF”. In normal operation the pump runs for less than 1 hour so the timer is not

called upon to perform the shutdown function. However, on vehicles with exceptionally large

tanks or excessive leaks the pump running cycle is extended. At times, with larger leaks the

pump will be forced to run continuously. This creates excessive heat in the pump cylinder and

subsequently higher wear on the piston seal. The Pump Timer provides a 1 hour cool down

time after 1 hour of operation to materially extend the life of the seal.

TYPES OF INSTALLATION

The motors used in the (2)different AC Auto Pumps are not identical. Therefore they have

different starting and running characteristics. The Model 091-9HP contains a permanent split

capacitor motor that has an inherently high starting torque. The Model 091-9B-1 utilizes a

shaded pole motor with a lower starting torque. The 091-9B-1 thus requires that the cylinder

head pressure must be relieved prior to starting. This pressure relief function is provided by the

Auto Drain and therefore the Auto Drain must be added to the Model 091-9B-1 when the

A.C. Auto Pump timer is installed. The 091-9HP will start without the Auto Drain.

CAUTION

DO NOT OPERATE THE MODEL 091-9B-1

WITH AUTO PUMP TIMER WITHOUT

AN AUTO DRAIN INSTALLED