Connections scheamtic – Kleenmaid CH40S User Manual

Page 9

background image

7

CONNECTIONS SCHEAMTIC

The hot plate is supplied with a power cable
(N2GMH2G types) prepared for 220...240V AC.
If the type of connections to which the hotplate is to be installed is other than
220 to 240 V Ac rmove the cable and make the connection according to the
adjacent drawings. (The cable must support temperatures of up to 120ºC).
The hotplate must be connected to the mains with a plug that meets the EEC
7 publication or with a multi-pole with a distance between the open contacts
of a least 3 mm.

This device conforms to European directives 73/23/Cee and 89/336/CEE

Total power
Hotplate: 60 cms., 6,3kW

PLATE

60 cms

27,5 A

32 A

220...240V~

14 A

16 A

220...240V~

Three phase

Voltage Tensión

Protection

Int.nominal

by phases

Protección

Int.nominal

por fases

PLATE

60 cms

11 A

12 A

380...400V~

16 A

20 A

380...400V~

Three phase

Voltage Voltage

Protection

Int.nominal

by phases

Protection

Int.nominal

by phases