INSTALLATION INSTRUCTIONS

VENTILATION OF ROOMS

The room in which this appliance is installed must be well ventilated by natural or mechanical means or

a combination of both to ensure correct combustion and the removal of spent air. The minimum

quantity of air for combustion will depend on the room volume, number of appliances and their total

power rating. The power rating of your appliance can be found by reference to the Rating Plate.

NOTE:

The actual ventilation requirements must be determined by reference to the Statutory

Regulations in force.

GAS CONNECTION

Data Label – The Data Label is located on the underside of the appliance. A duplicate label is supplied

to adhere in an accessible area adjacent to the appliance. This appliance is suitable for Natural Gas

and propane Gas; ensure that the available gas supply matches the Data Label.

Test Point Pressure – The appliance is factory set for Natural gas. The test point pressure should be

adjusted to 1.00 kPa with the relevant burners operating at maximum flame (see Table Page 7).

Natural Gas – 1.00 kPa

Propane Gas – 2.75kPa

When converting from Natural Gas to Propane ensure that the NG regulator is removed and replaced

with the Test Point Assembly. A gas regulator suitable for a supply pressure of 2.75 kPa should be part

of the gas tank supply. Replace the old data plate with one, which is suitable for the type of gas for

which the appliance has been regulated.

The gas supply must be connected by use of the ½ BSP Elbow, Seal and copper pipe and an isolation

tap fitted in an easily accessible position. For the location of the Gas Connection please refer to the

following table:

MODEL

Inlet Position

Inlet (mm)

from side

Inlet (mm)

from rear

CH311XFF

RHS Rear

30

30

CH311WOKFF

RHS Rear

35

30

CH607X CH607W

RHS Rear

30

30

CH609X CH609W

RHS Rear

30

30

CH611XFF CH611WFF

LHS Rear

50

40

CH711XFF

LHS Rear

105

40

CH911XFF

RHS Rear

55

40

CH915XFF CH915AFF

RHS Rear

40

40

CH920XFF

RHS Rear

60

45

FIG 2

The appliance as supplied is for use with Natural Gas, if it is to be adapted for LPG proceed as follows:

Isolate the appliance from the electricity and gas supplies.

Remove the pan supports and burner assemblies.

Replace the injectors with the alternative type supplied.

Use the appropriate thread sealant and check for gas soundness.

Affix the self-adhesive label to the Rating Plate to amend the Gas Category.