Operation disturbances, Ordering numbers – Kemppi TTC-TIG torches User Manual
Page 13

EN
4.
OperaTiOn disTurbanCes
4.1
The mOsT usual OperaTiOn disTurbanCes are as FOllOWs:
arc is not ignited:
• Cable is loose or there is a bad connection.
• Electrode of torch is highly oxidized (grey). Sharpen again lengthwise. Check that post
gas time is long enough. Check ignition by using pre-gas e.g. by 4-function operation of
torch.
• There are impurities in shielding gas (moisture, air).
• Protective hose or another insulation of torch is broken and ignition spark is “escaping”
from elsewhere than from electrode of torch.
• Torch is wet.
• At low current is used too big or blunt electrode.
gas shielding is bad (weld pool “is boiling”, electrode will be oxidized)
• There are impurities in shielding gas (moisture, air).
• There are impurities in base material (rust, base coat, grease).
• On gas nozzle or housing of tightening bushing has stuck “spatter”.
• Net of gas lens is damaged.
• There is too much draught at welding place.
• Note! With gas lens equipment you get a more balanced gas flow than with normal gas
nozzle equipment.
5.
Ordering numbers
4 m
8 m
16 m
TTC 130
627013004
627013008
627013016
TTC 130F
627013104
627016008
627013116
TTC 160
627016004
627066008
627016016
TTC 160S
627016204
627016208
627016216
TTC 220
627022004
627022008
627022016
TTC 200W
627020504
627020508
627020516
TTC 250W
627025504
627025508
627025516
TTC 250WS
627025704
627025708
627025716
11
TT
C / © Kemppi O
y / 1130