Technical information and guarantee clauses – Kemppi Minarc 110 User Manual
Page 9

©
COPYRIGHT
KEMPPI
OY
Minarc/0244 – 9
5. TECHNICAL INFORMATION AND GUARANTEE
CLAUSES
5.1. TECHNICAL INFORMATION
Minarc 140
Minarc 110
Connection voltage,
1 ~ phase 50/60Hz
220V-10%...240V + 6%
220V-10%...240V + 6%
Connection capacity
35 % ED
140 A
50 % ED
110 A
100 % ED
100 A
80 A
Mains cable/fuse, delayed
2,5 mm
2
S /3,3 m 16 A
1,5 mm
2
S /2,0 m 13 A
Welding current range,
Metal arc welding (MMA)
10 A/20,5 V...140 A/25,6 V
10 A/20,5 V...110 A/24,4 V
Electrodes, diameter
Ø1,5...3,25 mm
Ø1,5...2,5 mm
Welding current control range stepless
stepless
Open-circuit voltage
85V
85V
Open-circuit power
<10 W
<10W
Effi ciency
80%
80%
Power factor
0,60 (140A/25,5 V)
0,60 (110A/24,4 V)
Degree of protection
IP 23C
IP 23C
Temperature class
B (130°C)/H (180°C)
B (130°C)/H (180°C)
Range of working temperature -20...+40°C -20...+
40°C
Range of storage temperature -40...+60°C -40...+60°C
Degree of protection
IP23C
IP23C
Norms
IEC 974-1
IEC 974-1
EN 50199
EN 50199
External dimensions:
length
305 mm
123 mm
height
250 mm (207 mm)
250 mm (207 mm)
Weight
4,2 kg (4,8 kg)
4,2 kg (4,6 kg)
The unit fulfi ls CE marking demands.