8 – Minarc/0244
4.1. DAILY MAINTENANCE
Perform the following maintenance daily:
Clean electrode holder and TIG torch’s gas nozzle. Replace damaged or
worn parts.
Check TIG torch’s electrode. Replace or sharpen, if necessary.
Check tightness of welding and earth cables connections.
Check condition of mains and welding cables and replace damaged cables.
See that there is enough space in front and back of the unit for ventilation.
4.2. ORDERING NUMBERS
Item
Ordering
number
Minarc
140
welding
machine
6102140
(includes earth- and welding cables)
Minarc
110
welding
machine
6102110
(includes earth- and welding cables)
Earth
cable
and
clamp
6184005
Welding cable and electrode holder
6184015
Optional:
TIG torch TTM15V and welding cable
6271432
4.3. TROUBLESHOOTING
Main switch signal light is not lit.
Unit does not get electricity.
Check mains fuses and replace when necessary.
Check mains cable and plug, replace damaged parts.
Unit does not weld well.
Arc is uneven and goes off. Electrode gets stuck in weld pool.
Check welding settings and adjust when necessary. See 3. Use.
Check that earth clamp is properly fi xed and that contact surface is clean and
the cable is undamaged. See 3.4. Welding and 4.1. Daily maintenance.
Overheat signal light is lit.
The unit has overheated. See 3.2. Operating functions.
Check that there is ample space in front of and back of the unit for ventilati-
on.
Check welding settings. See 3.3. Welding selections.
If problems in use are not solved with above mentioned measures, contact Kemppi serv-
ice.