4.

setup features

Configuring additional features
The machine has additional features that can be selected and adjusted with the SETUP

feature. To activate and deactivate it, press both arrow buttons (3) simultaneously for at least 5

seconds.
In the SETUP mode, the display will show the name of the parameter to be adjusted and its

numerical value. Select the parameter to be adjusted with the arrow buttons and change the

parameter value with the control knob. The following parameters and values are available:

Name

displayed

Parameter

values

Factory

setting

Description

A

1/0

0

End current level selection, 1=I min / 0 =15%

b

1/0

1/0*)

Open-circuit voltage selection: 0 = 95 V, 1 = VRD 30 V / AU VRD 12 V

C

1/0

0

Forced stop during downslope with a brief pressing of the switch,
1 = On / 0 = Off

d

0...4

1

0 = 4T-LOG, 1 = Minilog, 2 = 4T-LOG + Minilog,
3 = Minilog + Search arc, 4 = 4T-LOG_4

E

5% ... 40%

20%

Start current level selection (% of the welding current)

F

1/0

0

Restore factory settings **), 1 = Restore / 0 = No restore

h

0.0...2.0 s

0

Minimum setting for pre-gas time

J

0...10 s

1 s

Minumum setting for post-gas time

L

5...20 s

10 s

Maximum setting for pre-gas time

o

15...99 s

30 s

Maximum setting for post-gas time

S

-3...5

0

Arc dynamics (Arc Force)

t

-9...0

0

Electrode ignition pulse (-9 = No pulse / 0 = Max pulse)

U

1/0

0

Disable automatic remote control recognition. 0 = Enable automatic
recognition, 1 = Disable automatic recognition.

*) Factory setting is 1 or 0 depending on the country where the product is sold. Restoring factory settings does not change
the value of this parameter.
**) Happens when exiting SETUP mode and value is 1.