4 additional features for mlp models, Kemppi oy / 1336 – Kemppi Evo 200 User Manual
Page 13

EN
3.4.4 additional features for mlp models
5.
ON
PANEL
HF
4T
2T
VRD
MINILOG
MINILOG
PULSE
A
ON
PULSE
S
MinarcTig
W005722
8.
11.
minilog
With the Minilog feature, you can switch between two current levels by pressing the switch
briefly. The levels are the welding current and the Minilog current.
To use the Minilog feature, press the button (5) so that the MINILOG indicator is lit. Use the
arrow buttons to move the selector to Minilog current and then set the desired Minilog
current level with the control knob (8).
The shielding gas starts to flow when the torch switch is pressed. When you release the switch,
the current starts to rise (if an upslope time is established) to the set welding current level.
Press the torch swich shortly (<1 sec) you can then easily switch up and down between the
two levels: welding current and Minilog current.
When you press the switch for 1 second and then release it, the current starts to decrease.
After a predetermined downslope time, the arc is disconnected.
pulse welding
To use the pulse welding feature, press the PULSE button (11) so that the ON indicator is
lit. Specify the desired welding current average (A) and pulse time (s). The machine will set
the remaining pulse values automatically. Manual adjustment for the peak and background
current and time settings are not available with this model.
11
© Kemppi Oy / 1336