2.1 removal from packaging
The equipment is packed in durable packages designed especially for it. However, it is
necessary to check the equipment before using it to make sure that the equipment or any part
of it has not got damaged during transportation. Also check that the delivery corresponds to
your order and that you have received all necessary instructions for installing and operating
the equipment. The packaging material is recyclable.
2.2 locating the machine
Place the machine on a horizontal, stable and clean ground. Protect the machine from rain
and direct sunshine. Check that there is enough space for cooling air circulation in front of and
behind the machine.
2.3 serial number
Serial number of the machine is marked on the rating plate. The serial number is the only
proper means of identifying parts for a specific product. It is important to make correct
reference to the serial number of the product when making repairs or ordering spare parts.
2.4 installation
1
2
3
5
4
6
7
8
1.
Function panel
2.
Remote control connector
3.
TIG torch control connector, not in MMA version
4.
Shield gas and current connector for TIG torch, not in MMA version
5.
(+) connector for electrode holder or earth cable, in TIG welding for earth cable
6.
(-) connector for earth cable or electrode holder in MMA welding (stick welding)
Markings for (+/-) poles on the machine front are embossed.
rear of machine
7.
Mains switch
8.
Snap connector for gas
Master, MasterTig, MasterCool 10