3.3.6 Welding voltage selections (VOLTAGE)

Select this menu item to change the welding voltage.

To change welding voltage, do the following

1.

Press the multi-function knob on the VOLTAGE menu item.

2.

Turn the multi-function knob to change the voltage value.

3.

Press the multi-function knob to accept the new voltage.

NOTE!

Voltage selection may be replaced by either FINETUNING (in pulsed or double-pulsed

processes) or BASECURRENT (in WiseRoot or WiseThin processes) setting.

3.3.7 Welding arc selections (ARC ON)

You can use this menu item to test MagTrac F 61 operation before starting the actual welding.

When the welding arc is OFF, the carriage performs the operations without igniting the

welding arc.

To turn the welding arc on or off, do the following

1.

Press the multi-function knob on the ARC ON menu item.

2.

Turn the multi-function knob to select ON or OFF.

3.

Press the multi-function knob to accept the value.

NOTE!

You can also use the ARC ON button turn the welding arc on and off.

3.3.8 Cycle weld selections (

CYCLE WELD)

With MagTrac F 61 you can use the cycle welding function, which means that the carriage

repeatedly welds a predefined length and then skips another predefined length.
In CYCLE WELD menu you can define the settings used in cycle welding.

Menu item

Values

Description

ON, OFF

Turn cycle welding on or off.

10mm…10.00m

Set the length of each weld.

10mm…2.00m

Set the length of the non-weld section between the welds.

CYCLE COUNT

CONT, 1…255

Set the number of cycles to be welded
– CONT means that the carriage continues cycle welding
continuously, until it is stopped.

When cycle welding is on, there is a cycle weld symbol (

) in the top right corner of the

MagTrac F 61 control panel display.

NOTE!

Crater fill feature is available in wire feeder control panel.

3.3.9 Gas test selections ( GAS TEST)

Select this menu item to test the gas flow. First select the menu item, and then start the gas

flow by pressing the multi-function knob or the soft key START. The shielding gas flows for 10

seconds.

NOTE!

You can interrupt the gas flow at any time by clicking the multi-function knob or the soft key

STOP.

3.3.10 Wire inch selections (WIRE INCH)

Select this menu item to run the filler wire into the welding gun. In MagTrac F 61, the wire inch

speed is always the same as the selected wire feed speed.

NOTE!

If the wire inch function is activated on the wire feeder's panel, the wire inch function on

MagTrac is not available.