Operations of remote control units – Kemppi Promig 100 User Manual
Page 16

16 – Promig 100/0450
©
COPYRIGHT
KEMPPI
OY
R20
R61
R63
R10
R61
RMT10
4. OPERATIONS OF REMOTE CONTROL UNITS
MIG
R63 Setting for wire feed: I 1…18m/min, II 1…25m/min
R61 Setting for voltage: 10 V…max. voltage of power source (35…45V)
Selecto
R63 Channel selection: 1…5 corresponding to settings 1, 4, 6, 8, 10 of knob
R61 Fine adjustment for arc length: 1…10
Synergic MIG
R63 Setting for power (wire feed speed): according to wire min. … max.
R61 Fine adjustment for arc length: 1…10
Synergic PULSMIG R63 Setting for power (wire feed speed): according to wire min. … .max.
R61 Fine adjustment for arc length: 1…10
MMA
R63 Setting for power: 10 A…max. power of power source
R61 NO OPERATION
MIG
R61 Setting for wire feed: I 1…18m/min, II 1…25m/min
Selecto
R61 Channel selection: 1...5 corresponds in the R10 settings 1, 4, 6, 8, 10 of knob
Synergic MIG
R61 Setting for power (wire feed speed): according to wire min …. max.
Synergic PULSMIG R61 Setting for power (wire feed speed): according to wire min. … max.
MMA
R61 Setting for power: 10 A…max.power of power source