5. MAINTENANCE
The amount of use and the working environment should be taken into consideration when
planning the frequency of maintenance. Careful use and preventive maintenance will help to
ensure trouble-free operation.
Daily
•
Daily check amount of liquid
IfIf cooling liquid has boiled, it must be replaced, because then the solution has lost
its metal coats protective effect.
Distilled water is not recommended to be used due to alga and bacterial flora which
tends to grow in it.
•
Daily check gaskets of welding ends and liquid hoses. Don’t use leleaking welding
ends or hoses!
Every six months
•
Replace cooling liquid and rinse tubes and reservoir with clean water.
Check that heat sensor is fastened with the reservoir!
•
Check connections of hoses and electric wires.
0ther repairs and mountings of mains connection cables should be carried out only
by an authorised electrician.
5.1. REGULAR MAINTENANCE
Kemppi service repair shops make regular maintenance according to agreement.
The major points in the maintenance procedure are listed as follows:
•
Cleaning of the machine
•
Checking of connectors and switches
•
Checking of electric connections
•
Checking of mains cable and plug
•
Damaged parts or parts in bad condition are replaced by new ones
•
Maintenance testing. Operation and performance values of the machine are checked,