Installation, Connection to the mains supply – Kemppi Procool 10 User Manual
Page 5

Procool 10/0109 – 5
©
COPYRIGHT
KEMPPI
OY
PRO 3200 Evolution
PRO 4200 Evolution
PRO 5200 Evolution
Procool 10
2. INSTALLATION
2.1. MOUNTING OF PROCOOL 10 UNIT ONTO
TRANSPORT CARRIAGE
1.
Place the Procool 10 unit onto transport carriage P30W 6185262 on left side of power source
in such a way that locking pins on bottom of the Procool 10 fit to holes of carriage. Push the
Procool backwards so that the unit would be locked onto the carriage. Finally lock the Procool
10 from the front side to transport carriage with latch plate and screw.
2.
Connect mains cable of the Procool 10 to earthed outlet of the PRO-power source.
3.
Connect control cable of the Procool 10 to unoccupied control connector of the power source
or to the MIG or TIG unit.
Before you connect the hoses make sure that they don’t bring dirt, metal powder etc.
To cooling liquid circulation system.
4.
Connect cooling liquid hoses to the MIG or TIG unit according to instructions. Note that
colour codes for hoses correspond to those colour codes which are on rear wall of the Procool
10 unit.
5.
The reservoir is filled with 40 % antifreeze according to British Standard BS3151. Filling
amount is approx. 3 l. Note in addition liquid tilling of interconnecting cables of approx.
1 1/15 m.
6.
Start the power source and the Procool 10. Press the switch S2 of the Procool 10 until the pilot
lamp H2 is swswitched off. Check still after that liquid level and return flow of the reservoir. Add
liquid when necessary. It is forbidden to use the switch s2 when the reservoir is empty!
Don’t swallow cooling liquid. If somebody has swallowed the liquid, send him imme-
diately to doctor. Avoid contact with skin and eyes. Wash with clean water.
2.2. CONNECTION TO THE MAINS SUPPLY
The Procool 10 unit is delivered equipped with 0,8 m mains cable with plug.
Mains cable is recommended always to be connected to the safety voltage schuko outlet of the
PRO power source.
Connection of the mains cable and mounting and change of the plug should only be carried
out by a competent electrician.
Before connecting the mains cable remove casing plate of the machine.