beautypg.com

Maintenance, 6 cooler operation, 7 overheat signal lamp – Kemppi KempCool 10 User Manual

Page 8: 8 storage

background image

EN

3. Connect the cooling water hoses with the wire feed unit, follow colour

markings.

4. Fill the reservoir with a 40 – 20 % mixture of etanol and water, or with

any other suitable antifreeze agent. The capacity of the reservoir is 3

litres.

5. Switch on the power supply.

6. Press and hold down the test switch until the torch hoses are filled with

liquid.

7. Device is ready to weld.

2.6

COOler OperatiOn

See also 2.4.2. Main parts of cooling unit
KempCool 10 operation is controlled by the microprocessor of the power

supply. The cooler pump starts to operate when the welding begins. After

the welding has stopped, the pump will operate 1 to 5 minutes longer

depending on the welding time. During this time the liquid will cool down

to the surrounding temperature. If the pump is stopped, the need for

maintenance of the cooler will be reduced.
Check the tank liquid level regularly and fill in liquid, if necessary.
If the the container has ran out of liquid the welding is stopped and error

code, Err 5, appears on the KempArc panel.

2.7

Overheat signal lamp

The overheat signal lamp is lighting when temperature control of the

machine has detected cooling water overheat. The ventilator cools down the

machine and when the lamp goes out welding can be started again.

2.8

stOrage

The machine must be stored in a clean and dry room. Protect the machine

from rain and keep it away from direct sunshine in places where temperature

exceeds +25 °C. Check that there is free space in front of and behind the

machine for air circulation.

3.

maintenanCe

NOTE!

Watch out for mains voltage when handling electric cables!

In planning product maintenance machine utilization degree and

circumstances should be considered. Careful use and preventive

maintenance help to avoid unnecessary production disturbances and breaks.

6

KempC

ool 10 / © Kemppi O

y / 1038