beautypg.com

En 5. trouble shooting, Technical data – Kemppi KempCool 10 User Manual

Page 10

background image

EN

5.

trOuble shOOting

See also 2.7. Overheat signal lamp.

Overheat signal lamp is lit.

The unit is overheated.

• Check water circulation.

• Check that there is enough free space behind the machine for cooling air

circulation.

error code err 5/err 27 on the panel

• Check the liquid hoses for damages.

• Remove any hose blockages.

• Check water circulation, add liquid if needed.

For further information and assistance, contact your nearest Kemppi service

workshop.

6.

teChniCal Data

Cooling unit KempCool 10
Operating voltage

400V -15%. …+20%

Connection capacity

100 % ED

250 W

Cooling power

1 kW

Start pressure, max.

0.4 MPa

Cooling liquid

20 % – 40 % etanol/water

Tank volume

3 l

External dimensions

LxWxH

570x230x280 mm

Weight

11 kg

Operating temperature range

-20 … +40 °C

Storage temperature range

-40 … +60 °C

EMC class

A

Degree of protection

IP23S

8

KempC

ool 10 / © Kemppi O

y / 1038