4.

using the mAChine

Before starting to use the Kemppi ArcFeed wire feeder, you must be aware of the power

source type you are using ( either CC, constant current, or CV, constant voltage). The suitable

welding wire for the welding application must also be loaded in the feeder. For more

information, see Chapter 3.

4.1

using the COntrOl pAnel FunCtiOns

1

2

3

4

5

6
7

1.

ON/OFF switch

2.

Gun operating mode selector (2T/4T)

3.

CC/CV mode selector

4.

Selector of the wire feed speed scale

5.

Control knob.

6.

Polarity indicator light

7.

LCD display

4.1.1 switching the machine on and off

To turn on the machine, set the main switch (1) to position ON. The LCD display of the control

panel lights up, and the machine is ready for use.

4.1.2 selecting the CC or Cv mode

With the CC/CV switch you can choose between constant current (CC) and constant voltage

(CV) type of power source. Set this switch according to the power source you are using. See

the documentation of the power source to find its type.