Technical Specifications

Quick Reference Guide

35

Print Contrast Minimum

15% minimum reflectance

Decode Capability

UPC/EAN/JAN, P2 /P5 add-ons; Code 39; Italian
Pharmacode 39; Code 128; C128 ISBT; Code 128 add-
ons; I 2 of 5; Standard 2 of 5; Code 11;Codabar; EAN
128; Code 93; MSI; GS1 DataBar™ Omnidirectional,
GS1 DataBar™ Limited, GS1 DataBar™ Expanded;
Code4, Code5.

Interfaces Supported

d

RS-232 Std, RS-232 Wincor-Nixdorf, RS-232 OPOS,
IBM 46xx (ports5B and 9B), USB Com Std., USB Key-
board, USB Alternate Keyboard, USB OEM, Keyboard
Wedge (AT with or w/o Alternate Key, IBM AT PS2
with or w/o Alternate Key, PC-XT, IBM 3153, IBM Ter-
minals 31xx, 32xx,34xx, 37xx make only and make
break keyboard, Digital Terminals VT2x, VT3xx,
VT4xx, and Apple) and Wand Emulation.

User Environment

Operating Temperature

32° to 122° F (0° to 50° C)

Charging Temperature

32° to 104° F (0° to 40° C)

Storage Temperature

-4° to 158° F (-20° to 70° C)

Humidity

Operating: 5% to 90% relative humidity,
non-condensing

Drop Specifications

Scanner withstands 18 drops from 1.8 meters
(5.9 feet) to concrete

Ambient Light Immunity

Up to 100,000 Lux

Contaminants Spray/rain
Dust/particulates

IEC 529-IP52 (scanner only)

ESD Level

16 KV

a.

Charge Times are much lower when battery is within daily typical operat-
ing condition.

b. Typical input current measured under factory default configuration.

c.

13 mils DOF based on EAN. All others are Code 39. All labels grade A, typi-
cal environmental light, 20°C, label inclination 10°

d. See Interface Selection on page 22 for a listing of available interface sets

by model type.

Item