Disconnect drain trap from waste discharge tube.
Disconnect dishwasher or direct water connection if
connected to the disposer.
Support disposer, insert end of wrenchette into right
side of mounting lug, and turn. Disposer will fall free.
With the electrical supply turned off, flip disposer
over and remove electrical cover plate. Save cable
connector if applicable.
With the electrical supply turned off, disconnect the
disposer wires from the electrical supply.
Removing Existing Disposer
1
3
2
5
!
*
4
If there is no existing disposer, disconnect sink drain and skip to step 9.
FALLING HAZARD
Do not position your head or body under the
disposer. It could fall during installation.
ELECTRICAL SHOCK
Disconnect power before installing or servicing unit.
Test the circuit with a voltmeter or circuit tester to
ensure the power is off.