Specifications

2013-03-11

43

7.1.1 Serial Interface

The serial interface option supports a

full-duplex transmission

with a real

hardware handshake up to a Baud rate of 19,200 Baud.

The CON Unit is cabled as DTE (Data Terminal Equipment, like CPU
output) and can be connected directly to DCE devices (Data
Communication Equipment).

A touch screen can be connected directly to the CON Unit.

To connect to a serial printer (or any other DTE instead of DCE
device), you need a null modem cable (crossed cable) between CON
Unit and the device.

Operation of several devices:

The serial interface transmits 6 signals (3 for each direction).

Normally,

4 of the 6 signals are handshake signals (in addition to RxD and TxD).

The following configurations, however, can be realized using special
adapter splitting cables:

Three single 2-wire transmissions

Two transmissions with a handshake signal

A serial mouse and a single 2-wire transmission.

In this case, choose X-ON / X-OFF software handshake for traffic control
at printer and PC.

Connection Format

DTE (Data Terminal Equipment)

Speed

Up to 19,200 Baud

Data Format

Format independent

Data Transmission

RxD

(Receive

Data)

TxD (Transmit Data)

Traffic Control

The following signals are transmitted
(hardware handshake):

RTS (Request To Send)

CTS (Clear To Send)

DTR (Data Terminal Ready)

DSR (Data Set Ready)

Pos: 45 /806-IHSE/Technische Daten/Schnittstellen/Analoge Audio-Schnittstelle @ 5\mod_1291127716734_6.doc @ 44846 @ @ 1