11 status led, 12 maintenance, repair and disposal, 13 approvals/standards – ifm electronic JN2300 User Manual
Page 22: 14 factory setting

Inclination sensor JN
22
The default setting of the programming key is:
j4w+ZEgRKHAl5Y8=
11 Status LED
The integrated LED indicates the current device state�
LED colour
Flashing frequency
Description
Green
Permanently on
The device is in the "run" state
12 Maintenance, repair and disposal
The unit is maintenance-free�
► Dispose of the device in accordance with the national environmental
regulations�
13 Approvals/standards
The CE declaration of conformity and approvals can be found at:
www.ifm.com → Data sheet search → JN2300
14 Factory setting
Index
Type
Value
Delivery
0x1000
u8
TxPGN0 active
1: is sent cyclically
0x2000
u8
Device address
25
0x2001
u16
Baud rate
250 Kbits
0x2040
u8
Flag for quadrant correction
2: corresponds to "0° ��� 360°”
0x2041
u8
Flag for heating
1: corresponds to "heating on"
0x2042
u8
Index teach value of the X/Y/Z axes
2: corresponds to "absolute measurement"
0x2043
u8
FIR filter step
2: corresponds to "FIR lowpass 5Hz"
0x2044
u8
Angle calculation
0: corresponds to "perpendicular"
0x2045
u8
CAN 120 Ω terminating resistor
1: corresponds to "activated"
0x2046
u8
Set zero point of the X/Y axes
2: corresponds to "absolute measurement"
0x2047
u8
Output value
0: corresponds to "angle"
0x2048
u8
Axis selection
7: corresponds to "X/Y/Z" activated
0x2049
u8
FIR filter for V_eff
5: corresponds to "10���400 Hz"
0x204A
u8
Measuring range for V_eff / a_Peak
2: corresponds to "8g”