10.8 MEMS measuring cell temperature (0x2081)
The temperature of the measuring cell is determined every 200 ms and updated

in the protocol at "informative"� It can be read via access to the index 2081h� The

signed 16-bit value indicates the temperature in 1/10°C�
10.9 MEMS self-test (0x4008 / 0x4009)
To check the function of the measurement axes a self-test of the measuring cell

can be carried out�
The MEMS self-test (index 4008/01h) has to be activated by writing the value

1� The self-test takes about 2 s; when the self-test has ended, the flag (index

4008/01h) is reset to 0� The test result is coded in a byte and can be read from the

self-test register (index 4009h)�
00000111 of the 3 least significant bits code the internal X, Y, Z measurement

axes: axis faulty / bit 1: axis functional
10.10 Programming key (0x3000)
The sensor can convert the parameter setting unambiguously into a Base64-coded

key�
By means of this key sensors with the same parameter setting can be duplicated

in an easy way�
The programming key can be read from and written to index 3000h� To ensure

that only valid keys are accepted by the firmware a 2-byte checksum (CRC) is

calculated and added to the end of the key�
The following parameters are coded by the key

Parameter

Index

Sub-index

Node ID

0x2000

0x00

Baud rate

0x2001

0x00

Quadrant correction

0x2040

0x00

Heating

0x2041

0x00

Teach index

0x2042

0x00

FIR filter angle

0x2043

0x00

Angle calculation

0x2044

0x00

CAN 120 Ohm resistor

0x2045

0x00

Set zero point

0x2046

0x00

Output value

0x2047

0x00

Axis selection for Veff & aPeak

0x2048

0x00

FIR filter for vibration measurement

0x2049

0x00

Measuring range vibration measurement

0x204A

0x00