2 system settings 0x2000 - 0x207f) – ifm electronic JN2300 User Manual
Page 13

UK
Inclination sensor JN
13
8.2 System settings 0x2000 - 0x207F)
Index
Type
Value
Unit
R/W
Reset
0x2000
UNSIGNED8
Device address
default 25
R/W
X
0x2001
UNSIGNED16
Baud rate
default 250
Kbit
R
X
0x2002
UNSIGNED8
Flag to reset MC
flag = 1
→
MC reset
R/W
0x2040
UNSIGNED8
Flag for quadrant correction
0: off
1: on
→
± 180°
2: on
→
0° - 360°
R/W
0x2041
UNSIGNED8
Flag for heating
flag = 0
→
heating off
flag = 1
→
heating on
R/W
0x2042
UNSIGNED8
Index for teach values
of the X/Y/Z axes
0: no change
1: set teach, relative
measurement
2: reset teach, absolute
measurement
R/W
0x2043
UNSIGNED8
FIR filter step for angle
measurement
0 : FIR deactivated
1 : FIR lowpass 10Hz
2 : FIR lowpass 5Hz
3 : FIR lowpass 1Hz
4 : FIR lowpass 0�5Hz
R/W
0x2044
UNSIGNED8
Angle calculation
0: perpendicular
1: Euler
2: gimbal 1X
3: gimbal 1Y
R/W
0x2045
UNSIGNED8
CAN 120 Ohm terminating
resistor
0: resistor deactivated
1: resistor activated
R/W