INSTALLATIONS

JP6: LCD Panel Power Selection

JP6

LCD Panel Power

3.3V

5V

JP12: Clear CMOS Setting

JP13

Setting

Normal

Clear CMOS


JP1,JP2,JP3: RS232/422/485 (COM1) Selection

COM2~COM4 are fixed for RS-232 use only.
COM1 is selectable for RS232, RS-422 and RS-485.
The following table describes the jumper settings for COM1
selection.

COM1

Function

RS-232

RS-422

RS-485


Jumper

Setting

(pin closed)

JP3:

3-5 & 4-6

JP2:

3-5 & 4-6

JP1:

1-2

JP3:

1-3 & 2-4

JP2:

1-3 & 2-4

JP1:

3-4

JP3:

1-3 & 2-4

JP2:

1-3 & 2-4

JP1:

5-6








MI958 User’s Manual