STEP 9:

WITh The eLecTRIcAL PoWeR off, route

#14 gauge stranded copper wire from 12 VDC ground

and positive 2 VDC from the fuse panel through a 2-amp

fuse or circuit breaker. Leave at least 2 inches (305 mm)

of wire for connecting to toilet (fig. 9).

STEP 0: Connect the holding tank to the bottom of the

discharge flange.
STEP 11: Slide the four T-bolts into the slots of the floor

flange. Install the flange gasket over the T-bolts (fig.

0).

fig. 9

fig. 10

STEP 12: Install floor flange adapter with words “THIS SIDE

UP” facing up. Tighten adapter to floor flange using four

flat washers and hex nuts. Tighten in criss-cross pattern

(fig. 11).

STEP 13: Temporarily set the toilet in place on the floor

flange (fig. 14).

STEP 4: Mark the holes for the two toilet mounting

bolts (fig. 15).

fig. 16

STEP 5: Pick up toilet and set aside. Drill 3/6-inch

pilot holes in the floor (fig. 16).

fig. 15

STEP 16: With toilet close to floor flange, connect flex-

ible water supply hose to the water line fitting (fig. 17).

fig. 11

fig. 17

IMPoRTANT: If replacing an existing toilet with 2-bolt

floor flange, drill two 5/16-inch dia. holes in old floor

flange that align with two additional holes in floor

flange adapter. Use two #10 or 12 x 1-1/2-inch wood

screws and washers for these drilled holes, and two

T-bolts with flat washers and nuts to fasten flange

gasket and floor flange adapter to old floor flange.

do not use old hardware or seal.

fig. 14