Pac500 control cable with h401 or h601 -7 – Hypertherm H401 Power Supplies User Manual
Page 31

INSTALLATION
H401 & H601
Instruction Manual
3-7
5
PAC500 Control Cable with H401 or H601
The power supply control cable from the PAC500 console to the H401 or H601 power supply carries signals for the
contactor control relay, and the pilot arc ground. Note: For PAC500L use cable as designated in manual 800460.
Contactor control relay connection
Location: Power supply center wall
White wire #57
Black wire #58
Pilot arc ground connection
Location: +DC output
Red wire #27
Caution:
The power supply contactor (CON) is energized by the control relay (CR1).
Energizing the contactor directly with the plasma console circuitry will result
in damage to the console flow switches due to excessive inrush currents.
PAC500 Control Cable Connections
57
58
Machine Start
1 2 3
E F (ref)
27
Part No.
Length
028009
50 ft (15 m)
128088
150 ft (46 m)
128089
175 ft (53 m)
PAC500
Wire Terminal
2RECP End
Color
End
Connection
Function
2RECP-A
White
57
T-1
Machine Start
2RECP-B
Black
58
T-2
Machine Start
2RECP-C
Red
27
+ DC Output
P.A. Ground
2RECP-D
Green
Gnd
No Connection
Spare