beautypg.com

H601 power supply -3, H601 power supply – Hypertherm H401 Power Supplies User Manual

Page 23

background image

SPECIFICATIONS

H401 & H601

Instruction Manual

2-3

5

H601 Power Supply

Maximum OCV (U

0

)

400 VDC

Current Adjustment Range (I

2

)

200 to 750 A

Output Voltage (U

2

)

80 to 200 VDC (235VDC for high current cutting)

60% @ 150 kW, 104° F (40° C)

Duty Cycle Rating (X)

100% @ 120 kW, 104° F (40° C)

Temperature Rating

14° F ( -10° C) to 104° F (40° C)

Power Factor(cos

ϕ

)

0.47

Cooling

Forced Air (Class F)

Input Power (U

1

– Input Voltage; I

1

– Input Current)

036034

200 VAC (U

1

), 3 Phase, 50 Hz, 740 A (I

1

)

036032

400 VAC (U

1

), 3 Phase, 50 Hz, 370 A (I

1

)

036031

480 VAC (U

1

), 3 Phase, 60 Hz, 310 A (I

1

)

036033

600 VAC (U

1

), 3 Phase, 60 Hz, 246 A (I

1

)

Dimensions and Weight

Width

40" (1015 mm)

Maximum Height

53" (1345 mm)

Maximum Depth

50" (1270 mm)

Weight

2250 lbs (1022 kg)

This manual is related to the following products: