1 programming device codes, 2 deleting device codes, 3 enabling facility codes – DoorKing PC Compatible Multi-Door Access Controller 1838 User Manual
Page 33: 4 programming facility codes, 5 programming device codes
The PC programmable access control system must be equipped with a MemPLUS chip to program
device codes into its memory. Device codes must be five (5) digits in length and are typically card
and transmitter codes. Each device code that you enter is assigned to the directory code that you
select. Up to 25 device numbers can be entered under a single directory code, up to a maximum of
8,000 for the system. You cannot duplicate device codes.
3.5 PROGRAMMING DEVICE CODES
3.5.1
Programming Device Codes
This program sequence enters device (card, transmitter, digital) codes into the system memory.
1. Press
* 7 0 and enter the four-digit MASTER CODE _ _ _ _ (beep).
2.
Enter the directory code that the device code is to be assigned to (1, 2, 3 or 4 digits
depending on what was programmed in 3.4.1) then press * (beep).
3.
Enter the five-digit device code _ _ _ _ _ then press * (beep).
4.
Repeat steps 2 and 3 to enter additional device codes.
5. Press
0 # TOGETHER to end this programming step (beeeeeep).
3.5.2
Deleting Device Codes
This program sequence deletes individual device codes.
1. Press
* 7 1 and enter the four-digit MASTER CODE _ _ _ _ (beep).
2.
Enter the directory code (1, 2, 3 or 4 digits depending on what was programmed in
3.4.1) then press * (beep).
3.
Enter the five-digit device code _ _ _ _ _ then press * (beep).
4.
Repeat steps 2 and 3 to delete additional device codes.
5. Press
0 # TOGETHER to end this programming step (beeeeeep).
3.5.3
Enabling Facility Codes
This program sequence allows you to use (enable) or not use (disable) facility codes.
1. Press
* 7 2 and enter the four-digit MASTER CODE _ _ _ _ (beep).
2. Enter
0 to disable facility codes or enter 1 to enable facility codes then press * (beep).
3. Press
0 # TOGETHER to end this programming step (beeeeeep).
3.5.4
Programming Facility Codes
This program sequence enters device facility codes into the system memory. Up to 10 facility codes
(reference numbers 0 through 9) may be programmed. Valid facility codes are 000 – 255.
1. Press
* 7 3 and enter the four-digit MASTER CODE _ _ _ _ (beep).
2.
Enter the first facility code reference number _ (0 – 9) then press * (beep).
3.
Enter the three-digit facility code _ _ _ then press * (beep).
4.
Repeat steps 2 and 3 to enter additional facility codes.
5. Press
0 # TOGETHER to end this programming step (beeeeeep).
1838-065-L-3-10
Page
33