beautypg.com

Set ting the watch func tions – Highgear Altis User Manual

Page 11

background image

19

english

20

english

SET TING THE WATCH FUNC TIONS

SET TING THE WATCH FUNC TIONS

SETTING ALTIMETER

(continued)

The ALTIS is equipped with three altimeter Preset Locations. Preset Locations allow
you to pre-program 3 known altitudes into the watch’s memory. These presets allow
you to easily compensate for altitude drift caused by changes in atmospheric pressure
and are useful in the daily calibration process. If you know the exact altitude of a
particular place (example: your home, a favorite trail head or the base of your favorite
ski hill), you can preset your ALTIS to this location for quick calibration at that location.
You can also adjust the current altitude of your watch independent of the Preset
Locations.
In Altimeter Mode (any Altimeter screen except TEMP/Altitude/TIME):

1.

PRESS & HOLD

the

SET

key. Upper display line will flash name of selected

location (

CURRENT ALTITUDE, LOCAL 1, LOCAL 2 OR LOCAL 3

).

2.

SCROLL

through locations by

PRESSING

the

START/SPLIT

or

STOP

Key.

3.

When selected location is flashing in the upper display line,

PRESS

the

MODE

key to advance to set the Altitude of that location. The Altitude

display field will flash.

4.

ADJUST

Altitude by

PRESSING

the

START/SPLIT

(to increase) or

STOP

(to

decrease) key.

NOTE:

Press & Hold the Start/Split or Stop keys to fast scroll altimeter

setting.

5.

Once Altitude is adjusted,

PRESS

the

MODE

key to return to Altimeter

Setting Menu. Upper display line will flash. After all desired Altitude
Locations have been adjusted,

PRESS

the

START/SPLIT

key to continue

scrolling through Altimeter Settings.

RESETTING MAXIMUM AND ACCUMULATIVE ALTITUDE

6.

To

RESET MAXIMUM ALTITUDE

,

PRESS

the

MODE

key when

MAX

is flashing

in display. Maximum Altitude field will flash.

PRESS START/SPLIT

or

STOP

key to reset.

NOTE:

display will reset to O and assume current altitude reading when

you return to operation mode.

To preserve Max Altitude reading,

PRESS

the

START/SPLIT

key to

RETURN

TO ALTIMETER SETTING MENU.

7.

When ACC field is flashing,

PRESS

the

MODE

key to adjust. When the

Accumulative Vertical field is flashing,

PRESS

START/SPLIT

or

STOP

to

RESET

.

NOTE:

To preserve ACC reading, this step may be bypassed by Pressing

the Start/Split or Stop key when the ACC field is flashing and returning to
the Altimeter setting menu.

(

CONTINUED

NEXT

PAGE

)