5600 b, Henry engineering – Henry Engineering POWERSWITCH User Manual
Page 2

5
5
4
4
3
3
2
2
1
1
D
D
C
C
B
B
A
A
B
SEC
PRI
BLK/BRN
115V
230V
WHT/BLUE
1. ALL RESISTORS ARE 1/4W, 5%.
NOTE: UNLESS OTHERWISE SPECIFIED
GRN
GND
NC
COM
NO
FUSE-SIDE
AC INPUT
NEUTRAL
ON
A
B
ALARM
ALARM
MAIN-A
FUSE-TIP
BACKUP-B
B
A
B
GND
A
ON
OFF
RELAY DC
ALARM
5600
B
SCHEMATIC: AC SWITCHER
HENRY ENGINEERING
503 Key Vista Drive
Sierra Madre, CA 91024 USA
telephone - (626) 355-3656
FAX (626) 355-0077
1
1
Monday, December 29, 2008
Title
Size
Document Number
Rev
Date:
Sheet
of
+12V
+12V
+12V
+12V
+12V
+12V
+12V
+12V
JP1
1
2
3
D3
1N4004
E3
+
C1
1000uF 25V
C3
.1uF 50V
E4
E13
E7
RLY2
1
4
3
2
5
6
E1
Q1
2N4401
RLY1
1
4
5
2
3
Q2
2N4401
E14
U1D
CD4011BCN
12
13
11
TP2
1
E8
LED2
E2
R2
100K
LED4
R9
1.5K
M1
LED1
BZ1
1
2
+
-
J1
1
2
3
4
5
6
TP1
1
R1
10K
R3 100
R10
1.5K
C2
.1uF 50V
U1C
CD4011BCN
8
9
10
R6
10K
R4 100
D2
1N4004
R8
1.5K
SW1
2
1
3
E5
E10
E9
F1
115V: 250 ma; 230V: 125ma
T1
SPW-102
1
3
4
2
5
6
8
7
C4
.1uF 50V
E12
U1A
CD4011BCN
1
2
3
R11
1.5K
D4
1N4004
LED3
E6
D1
1N4004
R7
10K
E11
U1B
CD4011BCN
5
6
4