3 temperature query response, Temperature query response, Table 4: temperature query response packet – Digi M10 User Manual
Page 20
![background image](/manuals/77077/20/background.png)
Digi m10 Technical Overview
Digi International, Inc. © 2009
Page 20 of 26
4.3 Temperature Query Response
The Temperature Query Response packet (see
) is sent from the Digi m10 to the host
controller, indicating the satellite modem’s temperature in degrees Celsius.
Table 4: Temperature Query Response Packet
0
0x05/0x06
Packet Header
1
0x1A
Packet Type
2
Length0
Length of the packet
3
Length1
4
Retry_count/ Pkt Sequence Number
5
Temp0
Temperature value in
little endian
format.(This is a 32
bit floating point
number)
6
Temp1
7
Temp2
8
Temp3
9
Fletch0
Fletcher Checksum
10
Fletch1
NOTE: This packet is sent from the Digi m10 to DTE and it contains the current
temperature of the Digi m10 in degrees Celsius.