Greenheck Low-Profile Fan Coil (LFC) (464496) User Manual

Page 6

background image

6

Low-Profile Fan Coil

®

Unit
Size

A

B

4 row

6 row

8 row

C

D

C

D

C

D

30

12.00

7.00

0.625 0.625 0.625 0.875 0.625 0.875

45

12.00

7.00

0.625 0.625 0.625 0.875 0.625 0.875

50

13.50

7.75

0.625 0.625 0.625 0.875 0.625 1.125

65

17.00

9.50

0.875 0.875 0.875 1.125 0.875 1.125

85

17.00

9.50

0.875 0.875 0.875 1.125 0.875 1.125

All dimensions are in inches.

Unit
Size

A

4 row

6 row

8 row

B

C

B

C

B

C

15

5.75

0.625

0.625

0.625

0.625

0.625

1.375

20

7.0

0.625

0.625

0.625

0.625

0.625

1.375

25

8.0

0.875

1.375

0.875

1.375

0.875

1.375

30

9.5

0.875

1.375

0.875

1.375

0.875

1.375

45

9.5

0.875

1.375

0.875

1.375

0.875

1.375

50

10.75

0.875

1.375

1.125

1.375

0.875

1.625

65

13.00

1.125

1.375

1.125

1.375

1.125

1.625

85

13.00

1.125

1.375

1.125

1.375

1.125

1.625

All dimensions are in inches.

NOTE

With airflow from left to right, the fluid enters the coil
from the bottom connection (Inlet) and exits from the
top (Outlet). The other two coil connections should
be capped off (Cap)

Chilled Water • 4, 6 or 8 Row

Unit Size

A

4 row

6 row

8 row

B

B

B

15

7.63

0.75

0.75

1.375

20

10.13

0.75

0.75

1.375

25

12.63

0.875

0.875

1.375

30

15.13

0.875

0.875

1.375

45

15.13

0.875

0.875

1.375

50

17.63

1.375

1.375

1.625

65

22.63

1.375

1.375

1.625

85

22.63

1.375

1.375

1.625

All dimensions are in inches.

A

3.75

2

1.5

B

Copper Sweat

0.75

1

Drain Connection

3

Outlet

Airflow

Right side connection shown.

NOTE

With airflow from left to right, the fluid enters the coil
from the center connection (Inlet) and exits from the
bottom (Outlet). The other coil connections should
be capped off (Cap).

Direct Expansion (DX) • Single Circuit • 4, 6 or 8 Row

Distributor hookup is done inside module through 2-inch access hole.

Right side connection shown.

3.75

A

0.75

3

Outlet

1

Drain Connection

Airflow

B

Copper Sweat

C

Copper Sweat

2

1.5

NOTE

The first suction header on the entering air side of
the coil is circuited to the top distributor. With airflow
from left to right, the fluid enters the coil from the
center connection (Inlet) and exits from the bottom
(Outlet). The other coil connections should be
capped off (Cap).

A

B

0.75

3

Outlet

1

Drain Connection

3.75

Airflow

C

Copper Sweat

D

Copper Sweat

2

1.5

Direct Expansion (DXI) • Dual Circuit with 50/50 Face Interlaced Construction • 4, 6 or 8 Row

Distributor hookup is done inside module through 2-inch access hole.

Right side connection shown.