beautypg.com

Operation, Operational controls and adjustments – Delta GR150 User Manual

Page 9

background image

9 -

English

2. Align the holes in the eye shield with the holes in the spark guard. Place the eye shield spacer (A) Fig. 6 in the spark

guard.

3. Insert the eye shield bolt (A) Fig. 7 through the eye shield (B), the eye shield spacer (C), and the spark guard (D).

4. Place a 1/4" flat washer (E) Fig. 7 on the end of the eye shield bolt. Fasten the eye shield knob (F) on the end of the

eye shield bolt.

5. Assemble the other eye shield in the same manner.

FASTENING GRINDER TO SUPPORTING SURFACE

Disconnect machine from power

source!

If, during operation, there is any

tendency for the grinder to tip over, slide or "Walk",
the grinder must be secured to the supporting
surface using fasteners (not supplied) through the
two holes (A) Fig. 8 in the grinder base.

STARTING AND STOPPING GRINDER

The switch (A) Fig. 9, is located on the front of the grinder.
To turn the grinder "ON" move the switch right to the
"ON" position. To turn the grinder "OFF" move the switch
left to the "OFF" position.

Make sure that the switch is in the

"OFF" position before plugging in the power cord. In
the event of a power failure, move the switch to the
"OFF" position. An accidental start-up can cause
injury.

OPERATION

A

A

B

C

D

E

F

Fig. 6

Fig. 7

A

A

Fig. 8

OPERATIONAL CONTROLS AND ADJUSTMENTS

Fig. 9

A