Installation Instructions

ESD-635D

Florida Product Approval No: FL10088

Miami-Dade NOA No.: 12-0830.07

Maximum Wind-load: 150 PSF

Flange/Sleeve Installation

with VCD-40 Damper

Maximum Size and Installation Information

Model ESD-635D with VCD-40 is a Miami-Dade Qualified and Florida Product Approved louver and must be installed in
accordance with the installation instructions shown herein. Model ESD-635D with VCD-40 is qualified for installation within
concrete/masonry, steel stud, structural steel or wood framed building conditions. Model ESD-635D with VCD-40 is structurally
calculated to withstand positive and negative wind-loads up to 150 PSF. The maximum single section rough opening width is
36.50 in. The maximum single section rough opening height is 144.50 in. While the maximum rough opening height is limited to
144.50 in., the rough opening width is limited to 1,000 in. as multiple sections may be installed side by side in accordance with
installation instructions.

Minimum Rough

Opening Size

12 in. W x 15.25 in. H

Maximum Single Section

Rough Opening Size

36.50 in. W x 144.50 in. H

Building Condition/Substrate Limitations