beautypg.com

Installation instructions ehh-601d, Structure depth – Greenheck EHH-601D, Channel Installation (474643) User Manual

Page 8

background image

8

Installation Instructions

eHH-601D

Florida Product Approval No: FL10088

Miami-Dade NOA No.: 12-0830.08

Maximum Wind-load: 150 PSF

Channel Installation
Single Section

CMU / Concrete Substrate

• Min. structure depth 6.866 in.

• Max. structure depth infinite

Steel Stud / Structural Steel Substrate

• Min. structure depth 5.866 in.

• Max. structure depth infinite

Structure Depth

FASTENER SCHEDULE (FIELD INSTALLED - NOT BY GREENHECK)

CONCRETE

CMU

STEEL

MIN.

FASTENER TYPE

ALL FASTENERS ARE STEEL OR STAINLESS

JAMB PERIMETER ANGLE FASTNER

DIAMETER

# RQD.

CENTERS

EDGE

EMBED.*

X

2KSI

SCOTS TAPCON / TAPCON

1/4

VARIES

4.750

1.500

1.750

X

4KSI

SCOTS TAPCON / TAPCON

1/4

VARIES

6.000

1.500

1.750

X

1.5KSI

SCOTS TAPCON / TAPCON

1/4

VARIES

3.000

1.500

1.750

X

65KSI Fy

BOLT/NUT OR TAPPING SCREW

1/4

VARIES

6.000

0.500

0.125

MULLION END PLATE FASTENER, HEIGHT <=144

DIAMETER

# RQD.

CENTERS

EDGE

EMBED.*

X

2KSI

SCOTS TAPCON / TAPCON

1/4

9/END

2.000

1.500

1.625

X

4KSI

SCOTS TAPCON / TAPCON

1/4

8/END

2.000

1.500

1.625

X

65KSI Fy

BOLT/NUT OR TAPPING SCREW

1/4

8/END

1.000

0.500

0.125

MULLION ANGLE MOUNT FASTENER, HEIGHT <=144

DIAMETER

# RQD.

CENTERS

EDGE

EMBED.*

CENTER

X

2KSI

SCOTS TAPCON / TAPCON

1/4

32/ANG.

2.000

1.500

1.750

3.375

X

4KSI

SCOTS TAPCON / TAPCON

1/4

27/ANG.

2.000

1.500

1.750

3.375

X

1.5KSI

SCOTS TAPCON / TAPCON

1/4

32/ANG.

2.000

1.500

1.750

3.375

X

65KSI Fy

BOLT/NUT OR TAPPING SCREW

1/4

16/ANG.

1.000

0.500

0.125

3.000

X

65KSI Fy

BOLT/NUT OR TAPPING SCREW

1/4

11/ANG.

1.000

0.500

0.188

3.000

X

65KSI Fy

BOLT/NUT OR TAPPING SCREW

1/4

16/ANG.

1.000

0.500

0.188

3.766

MULLION END PLATE FASTENER, HEIGHT <=96

DIAMETER

# RQD.

CENTERS

EDGE

EMBED.*

X

2KSI

SCOTS TAPCON / TAPCON

1/4

6/CAP

2.000

1.500

1.750

X

4KSI

SCOTS TAPCON / TAPCON

1/4

6/CAP

2.000

1.500

1.750

X

65KSI Fy

BOLT/NUT OR TAPPING SCREW

1/4

3/CAP

1.000

0.500

0.125

MULLION ANGLE MOUNT FASTENER, HEIGHT <=96

DIAMETER

# RQD.

CENTERS

EDGE

EMBED.*

CENTER

X

2KSI

SCOTS TAPCON / TAPCON

1/4

11/ANG.

2.000

1.500

1.750

3.375

X

4KSI

SCOTS TAPCON / TAPCON

1/4

9/ANG.

2.000

1.500

1.750

3.375

X

1.5KSI

SCOTS TAPCON / TAPCON

1/4

11/ANG.

2.000

1.500

1.750

3.375

X

65KSI Fy

BOLT/NUT OR TAPPING SCREW

1/4

7/ANG.

1.000

0.500

0.125

3.766

X

65KSI Fy

BOLT/NUT OR TAPPING SCREW

1/4

6/ANG.

1.000

0.500

0.125

3.000

* EMBEDMENT DEPTH IS EQUAL TO OVERALL FASTENER LENGTH FOR CONCRETE/CMU FASTENERS. IF SHIMS ARE USED, FASTENER LENGTH MUST BE INCREASED BY THICKNESS OF SHIMS.