beautypg.com

Daewoo KOR-630A0A User Manual

Page 19

background image

18

CONDITION

CHECK

Check continuity of magnetron

Defective mag-

netron

RESULT

No

Continuity

CAUSE

REMEDY

Replace

Outlet has

proper volt-

age Fuse

does not

blow.

CONDITION

CHECK

Check continuity of primary inter-

lock switch

Malfunction of pri-

mary interlock

switch

RESULT

No

Continuity

CAUSE

REMEDY

Adjust or

replace

Turn table
motor and

oven lamp

do not turn

on

Check continuity of secondary

interlock switch

Malfunction of sec-

ondary interlock

switch

No

Continuity

Adjust or

replace

Check D.C. voltage being sup-

plied to RELAY (RY2) coil

Defective touch

control circuit

0 V

Replace

Faulty contacts of

RELAY (RY2) or

open relay coil

Approx.

12 VDC

Replace

Display do not shown

countdown

Malfunction of sec-

ondary interlock

switch

Replace

Check continuity of

power supply cord

Open power sup-

ply cord

No

Continuity

Replace

Defective touch

control circuit

Normal

Replace

NOTE
All these switches must be replaced at the same time, please refer to “Interlock Mechanism And Adjustment”.

(TROUBLE 2) Display shows all figures selected, but oven does not start cooking, even though desired program and

time are set and start button is tapped.

This manual is related to the following products: